Patients need to be aware of this and other factors that might give falsely low values. I have a good feel for how to adjust the device to optimize the recording, maximizing the pulse volume and the SpO2 recorded based on my hospital experiences. Wear it at different times during the day at rest and determine what your baseline normal SpO2 is. During my illness, I would measure my SpO2 twice daily and at times when I felt short of breath. If I had fully researched this topic prior to my impulse purchase on Amazon, I would have purchased the CMS50DL, since it has good bona fides from multiple studies.
Check back soon for the Skeptical Cardiologist's views on the new Apple Watch Series 6 and its blood oxygen sensor capability. Anthony C. Pearson, MD, is a noninvasive cardiologist and professor of medicine at St. Louis University School of Medicine. There is another consideration—some people stock up on anything that eases their fear and anxiety, says Dr. People are scared. That list includes cough, fever, shortness of breath, difficulty breathing, chills, repeated shaking with chills, muscle pain, headache, sore throat, and loss of taste or smell.
Click here to read about a philanthropic gift of wearable pulse oximeters to the Yale Medicine Department of Internal Medicine. Skip to Main Content. Thus, regarding the importance of continuous monitoring and maintaining hemodynamic stability in patients under heart surgery [ 29 ] and considering the results of our study, the earlobe probe can be used as the proper method for examining the oxygen saturation in patients under heart surgery.
In this study, the environmental light could intervene with the performance of each four pulse oximetry probes. However, a cover was put around the probes in order to prevent the intervention of environmental light with the performance of each four pulse oximetry probes.
Non-random sampling was used for this study which could affect the generalizability of the findings. Thus, it is suggested to replicate the study using random sampling in various patients. The study was conducted on the patients admitted to the intensive care unit for cardiac surgery and it is suggested to conduct the similar study on the patients admitted to emergency and operating rooms. Results of the study indicated that earlobe probe had higher accuracy in showing the SpO 2 among patients admitted to the intensive care unit for heart surgery compared to finger, toe and forehead probes and the obtained SpO 2 value of earlobe probe approximated to the SaO 2 obtained from ABG test.
Thus, earlobe probe can be used in intensive care units to measure the peripheral oxygen saturation. This work was perform in partial fulfillment of the requirements for MSc.
This article was drawn from a research project No. We appreciate Clinical research development Unit of Imam Reza Hospital and patients who contributed to the study. This study was drawn from a research project No. The cost of the payment is spent on the design and implementation of the study. The study was approved by ethics committee of Kermanshah University of Medical Sciences with reference number ir.
Written consent was obtained from participants. Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. Sohila Seifi, Email: moc. Gholamreza Moradi, Email: moc. Alireza Abdi, Email: moc. Farid Najafi, Email: moc. National Center for Biotechnology Information , U.
BMC Nurs. Published online Apr Author information Article notes Copyright and License information Disclaimer. Corresponding author. Received Mar 20; Accepted Mar This article has been cited by other articles in PMC. Abstract Background Heart surgery patients are more at risk of poor peripheral perfusion, and peripheral capillary oxygen saturation SpO2 measurement is regular care for continuous analysis of blood oxygen saturation in these patients.
Methods In this clinical trial, 67 patients were recruited based on convenience sampling method among those admitted to intensive care units for coronary artery bypass surgery. Results Highest and lowest correlational mean values of SpO2 and SaO2 were related to finger and earlobe probes, respectively.
Conclusion The SpO2 of earlobe probes due to lesser mean difference, more limited confidence level and higher agreement ration with SaO2 resulted by arterial blood gas ABG analysis had higher accuracy. Keywords: Pulse oximetry, Critical care, Accuracy. Background Pulse oximetry is a simple and non-invasive method used to examine oxygen saturation SpO2 in various parts of body [ 1 ].
Results Of the 67 patients, Open in a separate window. Discussion In this study, the earlobe probes had the highest clinical agreement with SaO2 and higher accuracy due to less mean difference and limited confidence interval following by the finger, toe and forehead probes. Conclusion Results of the study indicated that earlobe probe had higher accuracy in showing the SpO 2 among patients admitted to the intensive care unit for heart surgery compared to finger, toe and forehead probes and the obtained SpO 2 value of earlobe probe approximated to the SaO 2 obtained from ABG test.
Acknowledgements This work was perform in partial fulfillment of the requirements for MSc. Funding This study was drawn from a research project No. Availability of data and materials Data available by contacting the corresponding author. Notes Ethics approval and consent to participate The study was approved by ethics committee of Kermanshah University of Medical Sciences with reference number ir.
Consent for publication Not applicable. Competing interests The authors declare there are no competing interests. Contributor Information Sohila Seifi, Email: moc. Most pulse oximeters show two or three numbers. The most important number, oxygen saturation level, is usually abbreviated SpO 2 , and is presented as a percentage. The pulse rate similar to heart rate is abbreviated PR, and sometimes there is a third number for strength of the signal.
Oxygen saturation levels are also generally slightly lower for those living at higher altitudes. Pulse oximeters have limitations and a risk of inaccuracy under certain circumstances.
In many cases, the level of inaccuracy may be small and not clinically meaningful; however, there is a risk that an inaccurate measurement may result in unrecognized low oxygen saturation levels.
Therefore, it is important to understand the limitations of pulse oximetry and how accuracy is calculated and interpreted.
FDA-cleared prescription pulse oximeters are required to have a minimum average mean accuracy that is demonstrated by desaturation studies done on healthy patients. However, real-world accuracy may differ from accuracy in the lab setting. While reported accuracy is an average of all patients in the test sample, there are individual variations among patients. The SpO 2 reading should always be considered an estimate of oxygen saturation.
Due to accuracy limitations at the individual level, SpO 2 provides more utility for trends over time instead of absolute thresholds.
Many patient factors may also affect the accuracy of the measurement. In the recently published correspondence by Sjoding, et.